[중고계측기] Keithley 2601A SourceMeter

코아텍계측기 2014. 3. 25. 15:48

 

전기,전자,통신용 중고계측기 매입/판매합니다.

제품문의

M.P : 010-오사일공-9508

E_mail : ct9508@naver.com

Homepage : www.coretech21.com







 

 

The Keithley 2601 SourceMeter lets you make precision DC, pulse, and low frequency AC source-measure tests faster, easier, and more economically than before. The Keithley 2601 offers two to four times the test speed of competitive products for I-V functional testing by combining:

  • Keithley’s high speed, third-generation Source-Measure Unit (SMU) design
  • An embedded Test Script Processor (TSP™)
  • TSP-Link™, a fast triggering and inter-unit communication bus
The Keithley 2601 has a single 40W, 3A channel and is electrically isolated to ensure high measurement integrity and wiring flexibility. The Keithley 2601 packs many instruments into a small package, including:
  • Aprecision power supply
  • A true current source
  • A 51/2-digit multimeter
  • A voltage or current pulse generator with measurement
  • A low frequency arbitrary waveform generator
  • An electronic load
  • A trigger controller
Features and Specifications of the Keithley 2601 include:
  • TSP-Link allows connection of multiple 2600 series instruments in a master/slave config allowing unlimited scalability
  • On-board Test Script Processor processes and runs complex sequences from the instrument - gives you up to 10X greater throughput
    • allows creation of custom measurement functions for components such as varistors, diodes and BJTs/FETs, or algorithm based tests like I-V sweeps with power compliance, linearity and latch-up test sequences, and thermal response tests.
  • Store up to 50,000 lines of TSP code and more than 200,000 readings in 16MB of nonvolatile memory.
  • Measure I and V at >10,000 readings/s. Execute a full source-measure cycle in just 200µs
  • Ensure repeatable timing and high throughput with the high speed auto-ranging function.
  • GPIB, RS-232 and 14-bit digital I/O interface ports are standard
  • Current measure range (per channel) 1pA to 3A
  • Current source range (per channel) 5pA to 3A
  • Basic current programming accuracy 0.03%
  • Basic current measurement accuracy 0.02%
  • Voltage measure range (per channel) 1µV to 40V
  • Voltage source range (per channel) 5µV to 40V
  • Basic voltage programming accuracy 0.02%
  • Basic voltage measurement accuracy 0.015%
  • Readings to memory 10,000/s
  • Sweep source change and reading to memory 5,500/s
  • Sweep source change and reading to GPIB 3,600/s
  • Spot readings to GPIB 1,100/s
  • Spot source change and reading to GPIB 880/s
  • Pulse capability 200µs minimum source/measure pulse

 

 

 

 